Ricoh D104 Field Service Manual page 874

Di-c1.5
Hide thumbs Also See for D104:
Table of Contents

Advertisement

3. Appendix: SP Mode Tables
Forced CPM Down Thresh:
No Duty Control
004
Specifies the threshold page for the forced processing stop without the duty limit.
Drum Stop Time: No Duty
Control
005
Specifies the drum brake time without the duty limit.
3
ITB Stop Time: No Duty
Control
006
Specifies the ITB brake time without the duty limit.
Forced CPM Down Thresh:
Duty Control
007
Specifies the threshold page for the forced processing stop with the duty limit.
Drum Stop Time: Duty Control
008
Specifies the drum brake time with the duty limit.
ITB Stop Time: Duty Control
009
Specifies the ITB brake time with the duty limit.
Duty Control: Start Time
010
Displays the execution time of the duty limit control.
FC Development Stop Time:
No Duty Control
011
Specifies the development stop time without the duty limit.
FC Development Stop Time:
Duty Control
012
Specifies the development stop time with the duty limit.
Duty Control Time
013
Specifies the duty control time.
156
*ENG
[0 to 5000 / 0 / 1 page/step]
*ENG
[300 to 1500 / 500 / 10 msec/step]
*ENG
[300 to 1500 / 500 / 10 msec/step]
*ENG
[0 to 5000 / 1 / 1 page/step]
*ENG
[300 to 1500 / 1500 / 10 msec/step]
*ENG
[300 to 1500 / 1500 / 10 msec/step]
*ENG
-
*ENG
[290 to 5000 / 290 / 10 msec/step]
*ENG
[290 to 5000 / 1550 / 10 msec/step]
*ENG
[0 to 300 / 30 / 1 min/step]

Advertisement

Table of Contents
loading

This manual is also suitable for: