Ricoh D104 Field Service Manual page 581

Di-c1.5
Hide thumbs Also See for D104:
Table of Contents

Advertisement

No.
Type
365
D
TD sensor (Vt low) error 2: M
366
D
TD sensor (Vt low) error 2: C
367
D
TD sensor (Vt low) error 2: Y
The Vt value of the black, magenta, cyan, or yellow TD sensor is below the specified
value with SP3020-004 (default: 0.5V) ten counts.
• TD sensor harness disconnected, loose, defective
• A drawer connector disconnected, loose, defective
• TD sensor defective
-
-
1. Check the black, magenta, cyan, or yellow TD sensor connector and harness
between the TD sensor and development unit for damage.
2. Check the drawer connector of the PCDU.
3. Replace the development unit.
4. Replace the PCDU.
No.
Type
372
D
TD sensor adjustment error: K
373
D
TD sensor adjustment error: M
374
D
TD sensor adjustment error: C
375
D
TD sensor adjustment error: Y
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC Tables
6
579

Advertisement

Table of Contents
loading

This manual is also suitable for:

D106

Table of Contents