Ricoh D104 Field Service Manual page 921

Di-c1.5
Hide thumbs Also See for D104:
Table of Contents

Advertisement

013 Total Collected Toner
014 Full Detection Date
3810
[ITB T-Collection Bttl Full]
Condition
001
Displays the current condition of the ITB toner collection bottle.
0: Factory default, 1: Before near full, 2; Near full, 3: Full, 4: Reserved
002 Detection Times
003 Print Page AF Near Full
004 Pixel Count AF Near Full
005 Pixel Count AF Replacement
Coefficient
008
Adjusts the toner amount between near full and full. (0.1 indicates 10%.)
Alarm Setting
011
NOTE:
If the toner collection bottle has been replaced before the machine detects used toner near
full when this setting is set to "0", the machine cannot detect toner collection bottle near full.
In that case, set SP3-902-017 to "1".
Displays the total amount from the near full
detection.
*ENG
[0 to 999999999 / 1 / 1]
Displays the date of the near full detection for
*ENG
the PCDU toner collection bottle.
*CTL
[0 to 4 / 0 / 1 /step]
Not used
*CTL
[0 to 50 / - / 1 /step]
Not used
*CTL
[0 to 2000 / 0 / 1 sheet/step]
Not used
*CTL
[0 to 200000 / - / 1 cm
Not used
Displays the pixel counter after replacement of
*CTL
toner collection bottle.
[0 to 200000 / - / 1 cm
*ENG
[0.1 to 1 / 1 / 0.1 /step]
Enables or disables the calling for @Remote.
[0 or 1 / 1 / - ]
*ENG
0: Enable @Remote calling
1: Disable @Remote calling
System SP3xxx
2
/step]
2
/step]
3
203

Advertisement

Table of Contents
loading

This manual is also suitable for:

D106

Table of Contents