Ricoh D104 Field Service Manual page 812

Di-c1.5
Hide thumbs Also See for D104:
Table of Contents

Advertisement

3. Appendix: SP Mode Tables
055 S. Cor.: 1200 Line: Y
056 S. Cor.: 1200 Subdot: Y
057 S. Cor.: 600 Subdot
058 Drum Cor.:600:Subdot
059 S. Cor.:1200 Subdot
060 Drum Cor.:1200:Subdot
3
[Line Pos. Adj. Offset] DFU
2182
(Color) M. Scan: Main scan, S. Scan: Sub-scan
High / Medium: 120 mm/sec, Low: 60 mm/sec
001 C Magnification
002 M Magnification
003 Y Magnification
004 M. Scan: High: Dot: C
005 M. Scan: High: Subdot: C
008 M. Scan: Low: Dot: C
009 M. Scan: Low: Subdot: C
010 M. Scan: High: Dot: M
011 M. Scan: High: Subdot: M
014 M. Scan: Low: Dot: M
015 M. Scan: Low: Subdot: M
016 M. Scan: High: Dot: Y
017 M. Scan: High: Subdot: Y
94
*ENG
[–16384 to 16383 / 0 / 1 line/step]
*ENG
[–1 to 1 / 0 / 0.001 line/step]
*ENG
[–1 to 1 / 0 / 0.001 line/step]
*ENG
[–7 to 7 / 0 / 1 /step]
*ENG
[–1 to 1 / 0 / 0.001 line/step]
*ENG
[–7 to 7 / 0 / 1 /step]
*ENG
Adjusts the line position manually.
[-1 to 1 / 0 / 0.001%/step]
*ENG
When line shifts are not corrected by the
automatic line position adjustment, do
this SP.
Increasing a value reduces the image in
*ENG
the main scan direction.
Decreasing a value enlarges the image
in the main scan direction.
*ENG
[-512 to 511 / 0 / 1 dot/step]
*ENG
[-15 to 15 / 0 / 1 pulse/step]
*ENG
[-512 to 511 / 0 / 1 dot/step]
*ENG
[-15 to 15 / 0 / 1 pulse/step]
*ENG
[-512 to 511 / 0 / 1 dot/step]
*ENG
[-15 to 15 / 0 / 1 pulse/step]
*ENG
[-512 to 511 / 0 / 1 dot/step]
*ENG
[-15 to 15 / 0 / 1 pulse/step]
*ENG
[-512 to 511 / 0 / 1 dot/step]
*ENG
[-15 to 15 / 0 / 1 pulse/step]

Advertisement