3. Appendix: SP Mode Tables
002 Execute:Mode b
003 Execute:Mode c
3
2112
[TM/P Sensor Test] ID Sensor Check FA
001 Execute
[Skew Adjustment]
Specifies a skew adjustment value for the skew motor M, C or Y.
2117
These SPs must be used when a new laser optics housing unit is installed, see "Laser Optics
Housing Unit" in the "Replacement and Adjustment" section.
001 Pulse: C
002 Pulse: M
003 Pulse: Y
2118
[Skew Adjustment]
001 Execute: C
002 Execute: M
003 Execute: Y
[Skew Adjustment Display]
2119
Displays the current skew adjustment value for each skew motor.
82
Executes the fine line position adjustment once.
-
If this SP is not completed, do SP2111-003 first and
then try this SP again.
Executes the rough line position adjustment once.
After doing this SP, make sure to execute
-
SP2111-001 or -002. Otherwise, the line position
adjustment is not perfectly done.
This SP is used to check the ID sensors at the factory.
The results of this SP are displayed in SP2140 to
SP2145.
*ENG
*ENG
[–75 to 75 / 0 / 1 pulse/step]
*ENG
*ENG
Changes the current skew adjustment values to the
values specified with SP2117.
*ENG
These SPs must be used when a new laser optics
housing unit is installed. For details, see "Laser
*ENG
Optics Housing Unit" in the "Replacement and
Adjustment" section.