Permit Temp.:Delta:Press:H-
humid
005
Specifies the threshold temperature for the curl control in high humidity.
[Stand-by Mode Setting]
006
P-Roll Thresh AF Job
CPM:M-humid
008
Specifies the CPM ratio of the decurl control against to the normal operation in middle
humidity.
CPM:H-humid
009
Specifies the CPM ratio of the decurl control against to the normal operation in high humidity.
1115
[Target Temp. Correction]
Temp.:Delta:End
001
Specifies the different temperature between end and center of the heating roller.
1132
[Maximum Duty Switch]
Control Method Switch
001
Selects the heater control method.
Use "1: Power Contro" if hot offset occurs after power-on and input voltage is relatively hight.
1141
[Fusing SC Issue Time Info]
001 SC Number
SC Cause
002
Shows the SC cause
0: Timeout 1, 1: Timeout 2, 2: Timeout 3, 4 to 9: Not used
Htg Roller:Ctr Diff1
101
Displays the calculated temperature at the center of the heating roller when an SC was issued.
*ENG
[0 to 200 / 100 / 1 deg/step]
*ENG
[0 to 160 / 100 / 1 deg/step]
*ENG
[0 to 100 / 80 / 1 %/step]
*ENG
[0 to 100 / 65 / 1 %/step]
*ENG
[-10 to 100 / 0 / 1 deg/step]
[0 to 2 / 0 / 1 /step]
*ENG
0: Fixed Duty, 1: Power Control
*ENG
Displays the issued SC number.
*ENG
[0 to 9 / - / 1/step]
*ENG
[-20 to 260 / - / 1 deg/step]