3. Appendix: SP Mode Tables
001 Plain: Bk
002 Plain: C
003 Plain: M
004 Plain: Y
009 Thick 2&FINE: Bk
010 Thick 2&FINE: C
3
011 Thick 2&FINE: M
012 Thick 2&FINE: Y
[Charge AC Current: LL] DFU
Charge Roller AC Current Adjustment for LL
(Color)
2007
Displays/sets the AC current target of the charge roller for LL environment (Low temperature
and Low humidity).
001 Environmental Target: Bk
002 Environmental Target: C
003 Environmental Target: M
004 Environmental Target: Y
[Charge AC Current: ML] DFU
Charge Roller AC Current Adjustment for MM (Color)
2008
Displays/sets the AC current target of the charge roller for ML environment (Meddle
temperature and Low humidity).
001 Environmental Target: Bk
002 Environmental Target: C
003 Environmental Target: M
004 Environmental Target: Y
72
*ENG
*ENG
*ENG
*ENG
[0 to 3000 / 2100 / 10V/step]
*ENG
*ENG
*ENG
*ENG
*ENG
[0 to 3000 / 610 / 10 A/step]
*ENG
[0 to 3000 / 630/ 10 A/step]
*ENG
[0 to 3000 / 610 / 10 A/step]
*ENG
[0 to 3000 / 670 / 10 A/step]
*ENG
[0 to 3000 / 610 / 10 A/step]
*ENG
[0 to 3000 / 630 / 10 A/step]
*ENG
[0 to 3000 / 610 / 10 A/step]
*ENG
[0 to 3000 / 660 / 10 A/step]