5. System Maintenance
The heating roller has two lamps. One heats the center of the heating roller and the other
heats both ends of the heating roller.
003 Pressure Center
005 Thermister Atmosphere
The pressure roller has no lamp.
1107
[Standby Target Temp. Setting]
Stanby/Preheat1: Center
001
Specifies the temperature of the heating roller for the ready or energy save 1 mode.
Stanby/Preheat1: Press
5
002
Specifies the temperature of the pressure roller for the ready or energy save 1 mode.
Preheat2: Center
003
Specifies the temperature of the heating roller for the energy save 2 mode.
Preheat2:Press
004
Specifies the temperature of the pressure roller for the energy save 2 mode.
Low Power:Center
005
Specifies the temperature of the heating roller for the low power mode.
Low Power:Press
006
Specifies the temperature of the pressure roller for the low power mode.
Print Ready:Center
007
Specifies the temperature of the heating roller for the print ready condition.
Print Ready:Press
008
Specifies the temperature of the pressure roller for the print ready condition.
1108
[After Reload/Job Target Temp.]
Center
001
Specifies the temperature of the heating roller after re-load or job.
330
-
[–10 to 250 / 0 / 1 deg/step]
-
[–10 to 250 / 0 / 1 deg/step]
*ENG
[100 to 150 / 135 / 1 deg/step]
*ENG
[0 to 200 / 0 / 1 deg/step]
*ENG
[0 to 200 / 130 / 1 deg/step]
*ENG
[0 to 200 / 0 / 1 deg/step]
*ENG
[0 to 200 / 0 / 1 deg/step]
*ENG
[0 to 200 / 0 / 1 deg/step]
*ENG
[120 to 150 / 130 / 1 deg/step]
*ENG
[0 to 200 / 10 / 1 deg/step]
*ENG
[120 to 150 / 130 / 1 deg/step]