[Toner End Prohibition Setting]
3519
Enables or disables each adjustment at toner end.
001 Process Control
002 MUSIC
003 TC Adjustment
3520
[ITB Idle Rotation]
001 Temperature: High
002 Temperature: Medium
003 Temperature: Low
004 Temp.: L: Power ON
005 to
Adjusts the threshold temperature for entering the ITB idle rotation after the process control.
011
005 Temp. Range Thresh:T2
006 Temp. Range Thresh:T1
010 Temp. Thresh:High
011 Temp. Thresh:Low
[Initial Process Control Setting]
Adjusts the threshold for the process control at power on.
3522
When the current condition has changed by more than the values of these SPs when
compared with the conditions at the previous operation, the process control at power on is
executed.
002 Non-use Time Setting
003 Temp. Change Thresh
004 Relative Humidity Range
005 Absolute Humidity Range
*ENG
[0 or 1 / 1 / 1/step]
0: Permit (adjustment is done even toner end
*ENG
condition)
1: Forbid (adjustment is not done at toner end
*ENG
condition)
*ENG
Specifies the idle rotation times of the ITB
*ENG
after the process control.
*ENG
[0 or 3 / 0 / 1 revolution/step]
*ENG
*ENG
[20 or 30 / 30 / 1 deg/step]
*ENG
[0 or 15 / 15 / 1 deg/step]
*ENG
[0 or 50 / 30 / 1 deg/step]
*ENG
[0 or 50 / 15 / 1 deg/step]
*ENG
[0 to 1440 / 360 / 1 minute/step]
*ENG
[0 to 99 / 10 / 1°C/step]
*ENG
[0 to 99 / 50 / 1 %RH/step]
*ENG
[0 to 99 / 6 / 1 g/m