Ricoh D104 Field Service Manual page 915

Di-c1.5
Hide thumbs Also See for D104:
Table of Contents

Advertisement

[Dev. DC Control:Display]
Normal: 120 mm/sec, Low: 70 mm/sec
3621
Displays the development DC bias adjusted with the process control for each line speed and
color.
001 Normal Speed:Bk
002 Normal Speed:C
003 Normal Speed:M
004 Normal Speed:Y
009 Low Speed:Bk
010 Low Speed:C
011 Low Speed:M
012 Low Speed:Y
[Development DC Control] DFU
3622
Adjusts the limit of VB.
001 VB Limit
[Charge DC Control: Display]
Normal: 120 mm/sec, Low: 60 mm/sec
3631
Displays the charge DC voltage adjusted with the process control for each line speed and
color.
*ENG
*ENG
*ENG
*ENG
[0 to 700 / 550 / 1 -V/step]
*ENG
*ENG
*ENG
*ENG
*ENG
[0 to 500 / 50 / 1 V/step]
System SP3xxx
3
197