002
Specifies the temperature of the pressure roller after re-load or job.
1111
[Environment Correction:Fusing]
Temp.: Threshold: Low
001
Specifies the threshold temperature for low temperature. If the fusing temperature is 17°C
or less, the machine executes the fusing mode for low temperature.
Temp.: Threshold: High
002
Sepcifies the threshold temperature for high temperature. If the fusing temperature is 30°C
or more, the machine executes the fusing mode for high temperature.
Low Temp. Correction
003
Specifies the additional temperature for the target temperature. If the fusing temperature is
in low temperature condition, this temperature is added to the taraget temperature.
High Temp. Correction
004
Specifies the additional temperature for the target temperature. If the fusing temperature is
in high temperature condition, this temperature is added to the taraget temperature.
005 Job Low Temp. Correction
006 Job High Temp. Correction
007 Job Low Temp. Correction:Sp. *ENG
Job High Temp.
008
Correction:Sp.
1112
[Image Process Temp. Correction]
These SPs are used for the fusing temperature control for variable job images. This control
saves the power comsumption when the machine copies or prints a job text image in black
and white mode.
Temp.:Normal:Center:Level1
001
Specifies the subtractive temperature level 1 of the fusing temperature control for variable
job images.
*ENG
[0 to 200 / 5 / 1 deg/step]
*ENG
[0 to 100 / 17 / 1 deg/step]
*ENG
[0 to 100 / 30 / 1 deg/step]
*ENG
[0 to 15 / 5 / 1 deg/step]
*ENG
[0 to 15 / 0 / 1 deg/step]
*ENG
[0 to 100 / 5 / 0.1 deg/step]
*ENG
[0 to 100 / 0 / 0.1 deg/step]
[0 to 100 / 10 / 0.1 deg/step]
*ENG
[0 to 100 / 0 / 0.1 deg/step]
*ENG
[-10 to 10 / 0 / 1 /step]
Main SP Tables-1