3. Appendix: SP Mode Tables
021 Average Coverage:3:C
022 Average Coverage:3:Y
Mode Counter:K
023
Displays the black print counter after the previous drum lubrication.
Mode Counter:CMY
024
Displays the color print counter after the previous drum lubrication.
3
[Color Regist Adjust]
These values are the parameters for the automatic line position adjustment and are adjusted
2101
at the factory. However, you must input a value for SP2101-001 after replacing the laser
optics housing unit. For details, see "Laser Optics Housing Unit" in the "Replacement and
Adjustment" section. The value should be provided with the new laser optics housing unit.
001 Bk: Main Scan: Dot
002 C Main Scan: Dot
003 M Main Scan: Dot
004 Y Main Scan: Dot
013 Bk: Sub Scan: Line
014 C: Sub Scan: Line
015 M: Sub Scan: Line
016 Y: Sub Scan: Line
[Magnification Adjust]
2102
These values are the parameters for the automatic line position adjustment and are adjusted
at the factory. These SPs must be input only when a new laser unit is installed.
78
*ENG
[0 to 100 / 0.05 / 0.01%/step]
*ENG
[0 to 100 / 0.05 / 0.01%/step]
*ENG
[0 to 999 / - / 1 page/step]
*ENG
[0 to 999 / - / 1 page /step]
*ENG
*ENG
[–512 to 511 / 0 / 1 dot/step]
*ENG
*ENG
*ENG
*ENG
[–16384 to 16383 / 0 / 1 line/step]
*ENG
*ENG