Ricoh D104 Field Service Manual page 759

Di-c1.5
Hide thumbs Also See for D104:
Table of Contents

Advertisement

010 Thin:FC:Press (DFU)
Thin:BW:Center
011
Usage Limitation:
+5°C against the default value is the upper limit for this setting.
012 Thin:BW:Press (DFU)
M-thick:FC:Center
013
Usage Limitation:
+10°C against the default value is the upper limit for this setting.
014 M-thick:FC:Press (DFU)
M-thick:BW:Center
015
Usage Limitation:
+10°C against the default value is the upper limit for this setting.
016 M-thick:BW:Press (DFU)
Thick1:FC:Center
017
Usage Limitation:
+5°C against the default value is the upper limit for this setting.
018 Thick1:FC:Press (DFU)
Thick1:BW:Center
019
Usage Limitation:
+5°C against the default value is the upper limit for this setting.
020 Thick1:BW:Press (DFU)
Thick2:FC:Center
021
Usage Limitation:
+5°C against the default value is the upper limit for this setting.
022 Thick2:FC:Press (DFU)
*ENG
[0 to 200 / 100 / 1 deg/step]
*ENG
[100 to 160 / 125 / 1 deg/step]
*ENG
[0 to 200 / 100 / 1 deg/step]
*ENG
[100 to 170 / 150 / 1 deg/step]
*ENG
[0 to 200 / 120 / 1 deg/step]
*ENG
[100 to 170 / 140 / 1 deg/step]
*ENG
[0 to 200 / 100 / 1 deg/step]
*ENG
[100 to 200 / 135 / 1 deg/step]
*ENG
[0 to 200 / 135 / 1 deg/step]
*ENG
[100 to 200 / 125 / 1 deg/step]
*ENG
[0 to 200 / 110 / 1 deg/step]
*ENG
[100 to 200 / 145 / 1 deg/step]
*ENG
[0 to 200 / 165 / 1 deg/step]
System SP1-xxx
3
41

Advertisement

Table of Contents