2. Make sure the horizontal lines are parallel.
"Parallel": The gap between horizontal lines is 1.8 mm or less.
3. If the lines are not parallel, check the following and apply corrections as necessary:
• Make sure that the side fences of the tray are set neatly against the sides of the paper.
• Make sure that the PTR unit is connected to the bracket correctly.
• Make sure that the shafts of the duplex unit are not bent nor damaged.
Adjusting the Trapezoid Image
1. Remove the following items:
• Fusing unit (
p.242)
• Front right cover (
• PCDU toner collection bottle (
• Inner cover (
• Inner right cover (
p.172)
p.165)
p.172)
p.171)
Troubleshooting Guide
6
655