Ricoh D104 Field Service Manual page 336

Di-c1.5
Hide thumbs Also See for D104:
Table of Contents

Advertisement

5. System Maintenance
Htg Roller:End Diff1
104
Displays the calculated temperature at the end of the heating roller when an SC was issued.
Htg Roller:End Det1
105
Displays the detected temperature at the end of the heating roller when an SC was issued.
Htg Roller:End Corr1
106
Displays the ambient temperature at the end of the heating roller when an SC was issued.
Press Roller Temp Value1
107
Displays the temperature at the pressure roller when an SC was issued.
Press Roller:End Temp Value1
5
108
Displays the temperature at the end of the pressure roller when an SC was issued.
Htg Roller:Ctr Diff2
151
SPs from -151 to -157 show previous fusing SC information.
152 Htg Rolloer:Ctr Det2
153 Htg Roller:Ctr Corr2
154 Htg Roller:End Diff2
155 Htg Roller:End Det2
156 Htg Roller:End Corr2
157 Press Roller Temp Value2
Htg Roller:Ctr Diff3
201
SPs from -201 to -207 show fusing SC information before previous fusing SC.
202 Htg Rolloer:Ctr Det3
203 Htg Roller:Ctr Corr3
204 Htg Roller:End Diff3
205 Htg Roller:End Det3
206 Htg Roller:End Corr3
207 Press Roller Temp Value3
334
*ENG
[-100 to 260 / - / 1 deg/step]
*ENG
[-10 to 260 / - / 1 deg/step]
*ENG
[-10 to 260 / - / 1 deg/step]
*ENG
[-10 to 260 / - / 1 deg/step]
*ENG
[-10 to 260 / - / 1 deg/step]
*ENG
[-200 to 260 / - / 1 deg/step]
*ENG
*ENG
*ENG
[-10 to 260 / - / 1 deg/step]
*ENG
*ENG
*ENG
*ENG
[-20 to 260 / - / 1 deg/step]
*ENG
*ENG
*ENG
[-10 to 260 / - / 1 deg/step]
*ENG
*ENG
*ENG