3. Appendix: SP Mode Tables
1113
[Curl Correction]
Execute Pattern
001
Selects the curl correction type.
-002 to
DFU
-006,
-008,
These SPs are desgined for the factory use only. Do not change the adjusted setting.
3
-009
Humidity:Threshold:M-
humid
002
Specifies the threshold between low and middle humidity.
Humidity:Threshold:H-humid *ENG
003
Specifies the threshold between middle and high humidity.
Permit Temp.:Delta:Press:M-
humid
004
Specifies the threshold temperature for the curl control in middle humidity.
Permit Temp.:Delta:Press: H-
humid
005
Specifies the threshold temperature for the curl control in high humidity.
[Stand-by Mode Setting]
006
P-Roll Thresh AF Job
Specifies the temperature of the pressure roller for the stand-by mode.
CPM:M-humid
008
Specifies the CPM ratio of the decurl control against to the normal operation in middle
humidity.
CPM:H-humid
009
Specifies the CPM ratio of the decurl control against to the normal operation in high humidity.
52
[0 to 2 / 0 / 1 /step]
*ENG
0: OFF, 1: ON
*ENG
[0 to 100 / 65 / 1 %/step]
[0 to 100 / 80 / 1 %/step]
*ENG
[0 to 200 / 100 / 1 deg/step]
*ENG
[0 to 200 / 100 / 1 deg/step]
*ENG
[0 to 160 / 100 / 1 deg/step]
*ENG
[0 to 100 / 80 / 1 %/step]
*ENG
[0 to 100 / 65 / 1 %/step]