Chapter 1. System Programming (FF1)

Answer Supervision Timer

Software Version: CPC-B Version 4.0 or higher
Address: FF1 8# 4# 2# 8# (0-8)#
Description
When the DBS generates a call over the T1, answer supervision is provided to
determine if the call is actually answered. This timer determines how long
the offhook signal from the called party must last before the DBS treats the
offhook signal as an answer.
Programming
Table 1-44. Answer Supervision Timer values
Page 1-154
FF1 8# 4# 2# 8# (0-8)#
Setting
0
50 ms
1
100 ms
2
200 ms
3
600 ms
4
1000 ms
5
2000 ms
6
3000 ms
7
4000 ms
8
10,000 ms
DBS Manual - Revised April 2000
Section 400-Programming
Answer Supervision Timer setting
Default: 3 (600 ms) (see table below)