Sync Loss Counter - Panasonic DBS-2.3-400 Programming Manual

Table of Contents

Advertisement

Section 400-Programming

Sync Loss Counter

Software Version: CPC-B Version 4.0 or higher
Address: Master Cabinet: FF1 8# 4# 4# 3# 5# (0-9000)#
Slave Cabinet:
Description
Determines how many instances of sync loss must occur before a Sync Loss
Alarm FF key is lit. The FF key lights when the counter exceeds the specified
number within a 24-hour period.
For instructions on programming T1 alarm keys, see the T1 Reference
Manual (Section 500).
Programming
Related Programming
Sync Loss Relay: FF1 8# 4# (4 or 5)# 4# 3# (0 or 1)#
DBS-2.3/9.2-400
FF1 8# 4# 5# 3# 5# (0-9000)#
FF1 8# 4# (4 or 5)# 3# 5# (0-9000)#
4=Master Cabinet
5=Slave Cabinet
DBS Manual - Revised April 2000
Chapter 1. System Programming (FF1)
Instances of Sync Loss that must occur
within a 24-hour period before a
Sync Loss Alarm FF key is lit
Default: 9000
Page 1-181

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dbs-9.2-400

Table of Contents