Other Alarms Recovery

Software Version: CPC-B Version 4.0 or higher
Address: Master Cabinet: FF1 8# 4# 4# 2# 5# (0-15)#
Slave Cabinet:
Description
Determines how long the DBS tries to recover from an Out-Of-Frame (OOF),
Loss of Signal, Sync Loss, or AIS alarm before it re-syncs the T1 trunk.
Programming
Table 1-53. Other Alarms Recovery timer values
Related Programming
Other Alarms Detection: FF1 8# 4# (4 or 5)# 2# 4# (0-15)#
Notes
Power-Cycling Requirement. For changes to this parameter to take effect,
the system must be turned off, then back on.
Page 1-176
FF1 8# 4# 5# 2# 5# (0-15)#
FF1 8# 4# (4 or 5)# 2# 5# (0-15)#
4=Master Cabinet
5=Slave Cabinet
Setting
0
0 ms
1
250 ms
2
500 ms
3
750 ms
4
1000 ms
5
1500 ms
6
2000 ms
7
2500 ms
8
3000 ms
9
4000 ms
10
5000 ms
11
6000 ms
12
7000 ms
13
8000 ms
14
9000 ms
15
10000 ms
DBS Manual - Revised April 2000
Section 400-Programming
Other Alarms Recovery timer setting
Default: 1 (250 ms) (see table below)