Trunk Configuration: FF1 8# 4# (4 or 5)# 1# 1# (0 or 1)#
Number of T1 Channels: FF1 8# 4# (4 or 5)# 1# 2# (0-24)#
Trunk Circuit Type: FF2 (Trunk)# 21# (0-3)#
Notes
Loop-Start Card Version Requirement. This T1 Trunk Closure address
can only be used with the VB-43510A or VB-43511A versions of the loop-
start card.
CPC-B Versions Beginning With 6.03. The T1 Trunk Closure address is
no longer present. Instead, simply use the Trunk Circuit Type address (FF2
Trunk# 21#) to assign trunk ports as Loop Start, Ground Start, DID or T1.
Page 1-204
FF1 8# 7# (1 or 2)# (1-4)# (1-8)# (0 or 1)#
1=Master Cabinet
2=Slave Cabinet