Section 400-Programming

Transfer Extension

Software Version: CPC-AII (all versions); CPC-B Version 2.0 or higher
Address: FF4 3# (HuntGrp)# 3# (ExtNo.)#
Description
This program sets the extension number to which overflow calls will be
transferred.
Once all extensions in a hunt group have been searched, or after the Hunt
Group Transfer Timer has elapsed, the caller can be transferred to an
individual extension, an extension in a different hunt group, the Attendant, or
an SLT device.
Note: This address requires an extension number entry, rather than an
extension port entry.
Programming
To assign an overflow extension ...
To clear an overflow extension ...
Related Programming
Hunt Group Transfer Timer: FF4 3# (HuntGrp)# 4# (0-32)#
Notes
Overflow Extension Number Restriction. The overflow extension number
cannot be a hunt group pilot number.
Transfer Extension in Earlier CPC Versions. This address replaces the
Call Next Hunt Group address (FF4 3# HuntGrp# 2# HuntGrp#) used in
earlier CPC versions.
DBS-2.3/9.2-400
FF4 3# (1-8)# 3# (10-69 or 100-699)#
Hunt Group No.
FF4 3# (1-8)# 3# CONF ON/OFF
Hunt Group No.
DBS Manual - Revised April 2000
Chapter 4. Ringing and Hunt Groups (FF4)
Overflow Extension Number
Default: 000