Release Acknowledge Timer - Panasonic DBS-2.3-400 Programming Manual

Table of Contents

Advertisement

Chapter 1. System Programming (FF1)

Release Acknowledge Timer

Software Version: CPC-B Version 4.0 or higher
Address: FF1 8# 4# 2# 4# (0-15)#
Description
Determines how long the DBS waits for the CO to acknowledge a disconnect
signal (240 seconds by default).
Once this timer expires, the DBS will abandon the call even if the CO has not
acknowledged the disconnect. This allows the DBS to disconnect idle T1
trunks if the CO is not signaling properly.
Programming
Table 1-40. Release Acknowledge Timer values
Page 1-150
FF1 8# 4# 2# 4# (0-15)#
Setting
0
1 second
1
2 seconds
2
5 seconds
3
10 seconds
4
20 seconds
5
30 seconds
6
60 seconds
7
90 seconds
8
120 seconds
9
240 seconds
10
480 seconds
11
960 seconds
12
1,080 seconds
13
1,420 seconds
14
1,920 seconds
15
An infinite number of seconds
DBS Manual - Revised April 2000
Section 400-Programming
Release Acknowledge Timer setting
Default: 9 (240 seconds) (see table below)