Section 400-Programming
ISDN Support
Description
Hardware Requirements
The following are the minimum hardware requirements for ISDN support in the DBS:
•
ISDN Trunk Card (VB-43571)
•
CPC-EX (VB-43415)
•
SCC-B (VB-43421) (with ROM 1.3 or later)
•
MDF Card (VB-43562)
•
Sync Unit (VB-43563)
•
External CSU (not provided by Panasonic)
Setting Modified for ISDN
Programming
DBS-2.3/9.2-400
CPC-EX supports ISDN-PRI (Integrated Services Digital Network --
Primary Rate Interface). This ISDN Interface provides 23 voice channels
("B" channels) and a control channel ("D" channel) over a 4-wire circuit.
One program address, for Trunk Circuit Type (FF2 (trunk #)# 21#), has
been modified to allow for ISDN. This modification is described below. In
addition, CPC-EX provides several additional programming addresses to
support ISDN. The additional program addresses, as well as additional
detail on ISDN, are described in the ISDN Reference Manual, Part No.
504X00301A, Section 530.
to specify the Trunk Circuit Type...
FF2 (1-64)# 21# (0-5)#
Trunk Number
DBS Manual - Revised April 2000
Appendix C. EX 1.0 Feature Update
0=Loop start
1=Ground start
2=DID
3=T1
4=CID
5=ISDN
Page C-41