Dnis Number Setting - Panasonic DBS-2.3-400 Programming Manual

Table of Contents

Advertisement

Chapter 1. System Programming (FF1)

DNIS Number Setting

Software Version: CPC-B Version 4.0 or higher
Address: FF1 8# 4# 7# (DNISNo.)# (ExtNo.)#
Description
Use this address to assign DNIS number(s) to extension(s).
• Up to 500 different DNIS numbers can be assigned.
• One DNIS number can be assigned to multiple extensions (this takes up
• One extension can have multiple DNIS numbers assigned to it. (The
Programming
Related Programming
Multiple DID/DNIS: FF1 2# 1# 32# (0 or 1)#
DID/DNIS (enabling trunks for): FF1 8# 4# 6# (Trunk)# 2# (0-2)#
DNIS Flexible Ringing Assignments: FF1 8# 6# (DNISNo.)# (ExtNo.)#
Extension Numbers: FF3 (ExtPort)# 1# (ExtNo.)#
Notes
DNIS Requirement. DNIS is available only with the T1 interface.
Digit Length Requirement. The DBS supports 4-digit DNIS numbers with
either dial pulse or DTMF transmission.
DNIS Ring Control. Ringing for the DNIS number at the assigned
extension(s) is controlled by the next address (FF1 8# 6#).
Page 1-200
only one entry in the 500 available entries).
number of entries taken up is equal to the number of DNIS numbers
assigned to the extension.)
FF1 8# 4# 7# (0000-9999)# (10-69 or 100-699)#
4-digit DNIS Number
(0000[00]-1111[11])#
DBS Manual - Revised April 2000
Section 400-Programming
Extension Number
DBS-2.3/9.2-400

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dbs-9.2-400

Table of Contents