Failure Mode - Panasonic DBS-2.3-400 Programming Manual

Table of Contents

Advertisement

Section 400-Programming

Failure Mode

Software Version: CPC-B Version 4.0 or higher
Address: Master Cabinet: FF1 8# 4# 4# 1# 5# (0 or 1)#
Slave Cabinet:
Description
Determines the way the system responds to alarms. By default, the system
will continue to operate even if errors are detected.
Programming
Notes
Power-Cycling Requirement. For changes to this parameter to take effect,
the system must be turned off, then back on.
DBS-2.3/9.2-400
FF1 8# 4# 5# 1# 5# (0 or 1)#
FF1 8# 4# (4 or 5)# 1# 5# (0 or 1)#
4=Master Cabinet
5=Slave Cabinet
DBS Manual - Revised April 2000
Chapter 1. System Programming (FF1)
0=Mode 1 (the T1 continues to
operate even if errors
are detected)
1=Mode 2 (the T1 shuts down if
errors are detected)