Time Out For Dialed Did Digits - Panasonic DBS-2.3-400 Programming Manual

Table of Contents

Advertisement

Section 400-Programming

Time Out for Dialed DID Digits

Software Version: CPC-B Version 2.0 or higher
Address: FF2 (Trunk)# 24# (0-15)#
Description
This timer determines how long the DBS waits for DID digits, once CO
signaling has indicated that digits are to be transmitted (18 seconds by
default).
Programming
Table 2-4. DID Dialed Digit Timer values
DBS-2.3/9.2-400
FF2 (1-64)# 24# (0-15)#
Trunk Number
Setting
Value
0
No timeout
1
15 seconds
2
16 seconds
3
17 seconds
4
18 seconds
5
19 seconds
6
20 seconds
7
21 seconds
8
22 seconds
9
23 seconds
10
24 seconds
11
25 seconds
12
26 seconds
13
27 seconds
14
28 seconds
15
29 seconds
DBS Manual - Revised April 2000
Chapter 2. Trunk Programming (FF2)
Timeout setting for Dialed DID Digits
Default: 4 (18 seconds)
(see table below)
Page 2-23