Chapter 1. System Programming (FF1)
SLT Onhook Flash Timer
Software Version: All Versions
Address: FF1 3# 14# (0-6)#
Description
This timer determines how long an SLT user must hold down the switchhook
before the DBS recognizes a hookflash (200 ms by default). This address
also includes a setting that prevents hookflashes from being performed on
SLTs.
If you change this setting, you must turn the system off, then back on to
activate the change.
Programming
Table 1-21. SLT Onhook Flash Timer values
Notes
Power-Cycling Requirement. In order for changes to this program to take
effect, the system must be turned off, then back on.
Page 1-108
Address
Setting
No Detection
0
Less than 200 ms
1
Less than 200 ms
2
Less than 200 ms
3
Less than 200 ms
4
Less than 200 ms 200 to 1500 ms
5
Less than 200 ms
6
Less than 200 ms
DBS Manual - Revised April 2000
FF1 3# 14# (0-6)#
SLT Onhook Flash Timer setting
Default: 4 (valid flash=200 to 1500 ms)
(see table below)
Flash Treatment
Valid Flash
200 to 500 ms
200 to 700 ms
200 to 1000 ms
200 to 1200 ms
None
200-500 ms
Section 400-Programming
Disconnect
Greater than 500 ms
Greater than 700 ms
Greater than 1000 ms
Greater than 1200 ms
Greater than 1500 ms
Greater than 200 ms
Greater than 500 ms
DBS-2.3/9.2-400