Co Delayed Ring Timer; Table 1-33 Co Delayed Ring Timer Values - Panasonic DBS-2.3-400 Programming Manual

Table of Contents

Advertisement

Chapter 1. System Programming (FF1)

CO Delayed Ring Timer

Software Version: CPC-AII (all versions) and CPC-B Version 3.1 or higher
Address: FF1 3# 26# (0-15)#
Description
CO Delayed Ringing allows a second extension to ring when an incoming
trunk call is not answered at the first extension. This timer determines how
long a CO trunk call will ring at the first extension before it begins ringing at
the second extension. (When the second extension begins ringing, the first
extension will stop ringing.)
Programming

Table 1-33 CO Delayed Ring Timer values

Page 1-120
FF1 3# 26# (0-15)#
CO Delayed Ring Timer setting
Default: 2 (after 12 seconds) (see table below)
Setting
0
After 4 seconds
1
After 8 seconds
2
After 12 seconds
3
After 16 seconds
4
After 20 seconds
5
After 24 seconds
6
After 28 seconds
7
After 32 seconds
8
After 34 seconds
9
After 36 seconds
10
After 44 seconds
11
After 48 seconds
12
After 52 seconds
13
After 56 seconds
14
After 60 seconds
15
After 64 seconds
DBS Manual - Revised April 2000