Chapter 2. Trunk Programming (FF2)

Trunk Circuit Type

Software Version: CPC-AII and CPC-B (all versions)
Address: FF2 (Trunk)# 21# (Type)#
Description
This program determines the type of circuit for each trunk (Loop Start by
default).
NOTE: The circuit types available in each system depend on the CPC card
version. See "Notes" below for more information.
Programming
Related Programming
Call Duration Timer (for Caller ID): FF1 2# 1# 38# (0-2)#
Caller ID Automatic DISA Callers: FF1 2# 8# (1-10)# (PhoneNo.)#
T1 settings: FF1 8# 4# thru 7# addresses
Outbound Ground Start Detection Timer: FF1 3# 20# (1-8)#
Inbound Ground Start Detection Timer: FF1 3# 21# (1-8)#
DID Immediate or Wink Start: FF2 (Trunk)# 22# (0 or 1)#
Wink Start Timer: FF2 (Trunk)# 23# (0-15)#
Time Out for Dialed DID Digits: FF2 (Trunk)# 24# (0-15)#
DID Interdigit Timeout: FF2 (Trunk)# 25# (0-15)#
Notes
Power-Cycling Requirement. For changes to this parameter to take effect,
the system must be turned off, then back on.
Loop Start Circuit Type Considerations:
Page 2-18
FF2 (1-64)# 21# (0-4)#
Trunk Number
1. Loop Start is the most common type of CO line.
2. If a Ground Start Trunk Card is used, individual trunk ports on that
card can be set to "Loop Start".
DBS Manual - Revised April 2000
Section 400-Programming
0=Loop Start
1=Ground Start
2=Analog DID
3=T1
4=Caller ID (loop start)
DBS-2.3/9.2-400