Did Interdigit Timeout - Panasonic DBS-2.3-400 Programming Manual

Table of Contents

Advertisement

Chapter 2. Trunk Programming (FF2)

DID Interdigit Timeout

Software Version: CPC-B Version 2.0 or higher
Address: FF2 (Trunk)# 25# (0-15)#
Description
Once the CO begins to outpulse DID digits, this timer determines how much
time is allowed between each digit (80 ms by default). If the timer is
exceeded, the DBS returns the DID trunk to the idle state.
Programming
Table 2-5. DID Interdigit Timer values
Page 2-24
FF2 (1-64)# 25# (0-15)#
Trunk Number
Setting
Value
0
30 ms
1
40 ms
2
50 ms
3
60 ms
4
70 ms
5
80 ms
6
90 ms
7
100 ms
8
110 ms
9
120 ms
10
130 ms
11
140 ms
12
150 ms
13
160 ms
14
170 ms
15
180 ms
DBS Manual - Revised April 2000