Attendant Call Reversion Timer For Co Calls; Table 1-17. Attendant Call Reversion Timer Values - Panasonic DBS-2.3-400 Programming Manual

Table of Contents

Advertisement

Section 400-Programming

Attendant Call Reversion Timer for CO Calls

Software Version: All Versions
Address: FF1 3# 10# (0-12)#
Description
By default, the DBS will ultimately revert unanswered trunk recalls on
extensions to the Attendant phone. This timer determines how long an
unanswered trunk recall will ring at the last possible answering position
(extension) before it reverts to the Attendant phone (180 seconds by default).
This applies to trunk calls in the following states:
Programming

Table 1-17. Attendant Call Reversion Timer values

Related Programming
Extension Hold Recall Timer for CO Calls: FF1 3# 3# (0-12)#
Extension Transfer Recall Timer for CO Calls: FF1 3# 5# (0-12)#
Extension Park Hold Recall Timer: FF1 3# 9# (0-12)#
Notes
Night Mode Restriction. This feature is not available when the DBS is in
"Night" or "Night 2" mode.
DBS-2.3/9.2-400
• Hold recalls that are unanswered on the holding extension.
• Transfer recalls that are unanswered by the transferring extension.
• Park recalls that are unanswered by the parking extension.
Setting
0
No recall
1
20 seconds
2
40 seconds
3
60 seconds
4
80 seconds
5
100 seconds
6
120 seconds
7
140 seconds
8
160 seconds
9
180 seconds
10
200 seconds
11
220 seconds
12
240 seconds
DBS Manual - Revised April 2000
Chapter 1. System Programming (FF1)
FF1 3# 10# (0-12)#
Attendant Call Reversion Timer setting
Default: 9 (180 seconds) (see table below)