Address: FF7 1# 18# (ExtPort)# (0 or 1)#
Description
This Operator Access switch works only if the DBS system is set to use the
new NANP dialing plan (FF7 1# 17# 1#). Also, this switch applies only to
TRS types 2-6 (TRS types 0 and 1 do not allow outbound dialing; TRS type 7
allows all dialing).
Use this address to block extension(s) from being able to access a trunk and
dialing "0", "00", "10XXX0", or "101XXXX0" to reach an operator. This
prevents a user from being able to make a restricted phone call by asking the
operator to place the call for him.
Programming
Related Programming
Dialing Plan Switch: FF7 1# 17# (0 or 1)#
Notes
Timeout for Operator Calls. If this switch is set to "Deny" (default) and an
extension user accesses a trunk and dials the operator, the system will wait 6
seconds before automatically disconnecting the call. However, if the user
dials additional digits within the 6 seconds, the DBS will check other
switches such as "International Calling On Extensions", "7-Digit Toll
Restriction", etc., to allow or deny the call.
DBS-2.3/9.2-400
FF7 1# 18# (1-144)# (0 or 1)#
Extension Port
DBS Manual - Revised April 2000
Chapter 7. Toll Restriction (FF7)
0=Deny operator calls.
1=Allow operator calls.
Page 7-11