Extension Hold Recall Timer For Co Calls; Table 1-10. Extension Hold Recall Timer Values For Co Calls - Panasonic DBS-2.3-400 Programming Manual

Table of Contents

Advertisement

Chapter 1. System Programming (FF1)

Extension Hold Recall Timer for CO Calls

Software Version: All Versions
Address: FF1 3# 3# (0-12)#
Description
This timer determines how long a trunk call remains on hold at an extension
before it recalls (starts ringing the extension again; 140 seconds by default).
Programming

Table 1-10. Extension Hold Recall Timer values for CO calls

Related Programming
Attendant Call Reversion Timer for CO Calls: FF1 3# 10# (0-12)#
Notes
Recall Treatment for CO Calls. If a trunk recall is unanswered, it will revert
to the Attendant phone after ringing for the amount of time set in the
Attendant Call Reversion Timer.
Page 1-96
FF1 3# 3# (0-12)#
Extension Hold Recall Timer setting for CO calls
Default: 7 (140 seconds) (see table below)
Setting
0
No recall
1
20 seconds
2
40 seconds
3
60 seconds
4
80 seconds
5
100 seconds
6
120 seconds
7
140 seconds
8
160 seconds
9
180 seconds
10
200 seconds
11
220 seconds
12
240 seconds
DBS Manual - Revised April 2000
Section 400-Programming
Value
DBS-2.3/9.2-400

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dbs-9.2-400

Table of Contents