Section 400-Programming
Extension Hold Recall Timer for Intercom Calls
Software Version: CPC-AII (all versions) and CPC-B Version 2.0 or higher
Address: FF1 3# 23# (0-12)#
Description
This timer determines how long an intercom call will remain on hold at an
extension phone before it recalls (140 seconds by default).
Programming
Table 1-30 Extension Hold Recall Timer values for intercom calls
Notes
Recall Treatment for Intercom Calls. Unanswered recalls for intercom calls
will ring indefinitely at the extension.
DBS-2.3/9.2-400
FF1 3# 23# (0-12)#
Extension Hold Recall Timer setting for intercom calls
Default: 7 (140 seconds) (see table below)
Setting
0
No recall
1
20 seconds
2
40 seconds
3
60 seconds
4
80 seconds
5
100 seconds
6
120 seconds
7
140 seconds
8
160 seconds
9
180 seconds
10
200 seconds
11
220 seconds
12
240 seconds
DBS Manual - Revised April 2000
Chapter 1. System Programming (FF1)
Value
Page 1-117