Section 400-Programming

Hunt Group Members

Software Version: CPC-AII (all versions); CPC-B Version 2.0 or higher
Address: FF4 3# (HuntGrp)# (5-12 or 5-20)# (ExtNo.)#
Description
Use this program to assign an extension to a hunt group, and determine its
sequential position within the hunt group.
Programming
To assign an extension number to a position in a hunt group ...
To clear an extension from a hunt group position ...
Notes
Hunt Group Positions. With CPC-B versions between 2.0 and 5.x, there are 8
available positions in each hunt group. Beginning with CPC-B Version 6.0 and
CPC-AII, up to 16 positions are available.
Extensions. The extension numbers entered in this address must already be
assigned to extension ports in address FF3 (ExtPort)# 1# (10-69 or 100-699)#. An
extension cannot belong to more than one hunt group.
Hunt Group Pilot Number. A pilot number must be assigned to the hunt group in
address FF4 3# (HuntGrp)# 1# (11-69 or 101-699)#, in order for the hunt group
feature to work. However, do not include the pilot number here in Hunt Group
Members.
DBS-2.3/9.2-400
FF4 3# (1-8)# (5-12 or 5-20)# (10-69 or 100-699)#
Hunt Group No.
5=Position 1
6=Position 2
7=Position 3
8=Position 4
9=Position 5
10=Position 6
11=Position 7
12=Position 8
FF4 3# (1-8)# (5-20)# CONF ON/OFF
Hunt Group No.
NOTE: The extension must be idle while you are clearing it from the
hunt group position; otherwise, it will not be cleared.
DBS Manual - Revised April 2000
Chapter 4. Ringing and Hunt Groups (FF4)
Position
13=Position 9
14=Position 10
15=Position 11
16=Position 12
17=Position 13
18=Position 14
19=Position 15
20=Position 16
Positions 1-16 in Hunt Group
(using address numbers 5-20)
Extension Number
NOTE: Positions 9
thru 16 (address nos.
13-20) are available
only with CPC-AII/B
Version 6.0 or higher.