Chapter 1. System Programming (FF1)

RAI Baud Rate

Software Version: CPC-AII (all versions); CPC-B Version 1.0 or higher
Address: FF1 2# 2# 10# (0 or 1)#
Description
The baud rate used for the DBS's internal RAI modem can be set to 300 or
1200 bps. By default, 300 bps is used for remote programming.
Programming
Related Programming
Remote Programming ID Code: FF1 4# (0000-9999)#
Notes
Modem Card Requirement for Remote Programming. Remote
programming is provided through a modem card installed on the SCC card.
Two versions of the Remote Administration Interface (RAI) modem card are
available: RAI-A and RAI-B. The following table shows the transmission
rate of each card, along with the SCC version with which it can be used:

Table 1-5. RAI Modem Card Compatibility

RAI Version/Part No.
RAI-A (VB-43706)
RAI-B (VB-43707)
Restrictions for Two-Cabinet Systems Using Voice Mail. In dual-cabinet
DBS systems that have a Voice Mail system connected to an analog extension
port, the RAI card's baud rate must be set to 300 bps. See Technote 3 (April
1991) for complete information.
RAI Data Communications Parameters. When using the RAI card with
CPC-A, set the Serial Port parameters as follows:
In CPC-B configurations, the DBS will automatically set these parameters for
the RAI card.
Page 1-64
FF1 2# 2# 10# (0 or 1)#
• Parity: None
• Data Length: 8 bits
• Stop Bit Length: 1 bit
DBS Manual - Revised April 2000
Transmission Rate
300 bps
300 or 1200 bps
Section 400-Programming
0=300 bps
1=1200 bps
SCC Compatibility
SCC-A or SCC-B
SCC-B only
DBS-2.3/9.2-400