Modification To T1 Signaling Types; Outgoing Signaling Type - Panasonic DBS-2.3-400 Programming Manual

Table of Contents

Advertisement

Appendix C. EX 1.0 Feature Update
Hardware Requirements
• A printer or external call accounting system is required to receive SMDR
Considerations
• Unlike other CPC circuit cards, the CPC-EX supports two serial ports.
• Be sure to select the correct port to output SMDR data. From the

Modification to T1 Signaling Types

Description

Outgoing Signaling Type

Programming
Page C-44
data.
Serial Port 1 is labeled CN4 and is located on the backplane. Serial Port 2
is labeled CN5 and is located on the front of the CPC-EX card. Serial Port
2 requires a special interface cable.
Attendant's phone:
- dial #90 to set Serial Port 1 (the backplane port) to output Bus
Monitor/Maintenance and Serial Port 2 to no output.
- dial #92 to set Serial Port 1 to output SMDR and Serial Port 2
to output Bus Monitor/Maintenance data.
- dial #93 to set Serial Port 1 to output SMDR data and Serial
Port 2 to no output.
The default values for T1 Incoming and Outgoing Signal Types have been
changed to set "Wink Start" as the default. This will allow easier
programming of E&M trunks.
FF1 8# 4# 6# (1-64)# 3# (0-2)#
Trunk Number (1-64)
DBS Manual - Revised April 2000
Section 400-Programming
0=Immediate Start
1=Wink Start
2=Dial Tone Start
DBS-2.3/9.2-400