Section 400-Programming
AIS Relay
Software Version: CPC-B Version 4.0 or higher
Address: Master Cabinet: FF1 8# 4# 4# 4# 5# (0 or 1)#
Slave Cabinet:
Description
Determines whether the system closes the alarm relay on the T1 MDF card in
the event of Alarm Indication Signals (AIS), which are comprised of all 1's
and are unframed.
The alarm relay can be connected to an external alarm device such as a
buzzer. (This device must be purchased separately; it is not provided with the
DBS T1.)
Programming
Related Programming
Other Alarms Detection: FF1 8# 4# 4/5# 2# 4# (0-15)#
Other Alarms Recovery: FF1 8# 4# 4/5# 2# 5# (0-15)#
DBS-2.3/9.2-400
FF1 8# 4# 5# 4# 5# (0 or 1)#
FF1 8# 4# (4 or 5)# 4# 5# (0 or 1)#
4=Master Cabinet
5=Slave Cabinet
DBS Manual - Revised April 2000
Chapter 1. System Programming (FF1)
0=Off (AIS relay does not close)
1=On (AIS relay closes)
Page 1-187