Initializing Dbs Systems (Ramclr); Figure 1. Cpc Memory Clear Switch - Panasonic DBS-2.3-400 Programming Manual

Table of Contents

Advertisement

Introduction to DBS Programming

Initializing DBS Systems (RAMCLR)

After installing a new DBS system, or when upgrading
version, you must initialize the CPC (Central Processing Card) before
programming the system.
The procedure described below re-initializes the entire DBS memory, and
resets all programs to their default values. This means that all programs used,
as well as features set on individual extensions, must be reprogrammed. If
you have PCAS, you can download existing settings (thru CPC Version 4.0)
and upload them to the new version. The new features introduced in CPC
Versions 5.0 thru 6.1x, as well as the Permanent Call Forwarding feature,
must be manually reprogrammed.
1. Power-off the DBS (set power switch to OFF).
2. Slide the CPC's SW1 switch to "RAMCLR".
3. Power-on the DBS. Wait until the bottom status LED on the CPC card
4. Slide SW1 back to "RAMHOLD".
5. From any display phone, verify the software version by pressing
Figure 1.
CPC memory clear switch
TRK1 TRK2 TRK3
Intro-4
IMPORTANT: This procedure must be performed before you program
the DBS system. Failure to initialize the CPC before programming may
cause operational problems.
stops flashing (this takes less than a minute).
ON/OFF CONF 7777
EC1
EC2
EC3
EC4
EC5
EC6
DBS Manual - Revised April 2000
EC7
EC8 EC/ TRK SCC
CPC
AUX1 AUX2
Section 400-Programming
to a higher-level
STATU S
LED
SW 1
R A M H O LD
R A M C LR
DBS-2.3/9.2-400

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dbs-9.2-400

Table of Contents