Wink Start Timer

Software Version: CPC-B Version 2.0 or higher
Address: FF2 (Trunk)# 23# (0-15)#
Description
This timer determines the duration of the "wink" that is sent to the CO
following the CO's seizure of a DID trunk (200 ms by default).
At the conclusion of the wink, the CO transmits the DID digits to the DBS.
Programming
Table 2-3. Wink Start Timer settings
Page 2-22
FF2 (1-64)# 23# (0-15)#
Trunk Number
Setting
Value
0
140 ms
1
160 ms
2
180 ms
3
200 ms
4
220 ms
5
240 ms
6
260 ms
7
280 ms
8
300 ms
9
320 ms
10
340 ms
11
360 ms
12
380 ms
13
400 ms
14
420 ms
15
440 ms