Aec Disconnect Signal Duration - Panasonic DBS-2.3-400 Programming Manual

Table of Contents

Advertisement

Section 400-Programming

AEC Disconnect Signal Duration

Software Version: CPC-A Version 3.3 or higher
Address: FF1 2# 1# 23# (0-15)#
Description
Use this address to set the AEC card (VB-43621A) to provide a positive
disconnect signal, and determine the duration of the signal. By default, the
disconnect signal is not sent.
If set, analog extension ports will provide a disconnect signal (open loop)
upon hangup. Sending this signal allows quick disconnect from third-party
voice mail systems.
Programming
Related Programming
AEC Disconnect (CPC-A 3.3 or higher): FF3 (ExtPort)# 35# (0 or 1)#
AEC Disconnect (CPC-AII/B 5.0 or higher): FF3 (ExtPort)# 46# (0 or 1)#
Notes
AEC Disconnect Signal Duration for CPC-B Versions. For CPC-B Version
5.0 and higher, the AEC Disconnect Signal Duration is set in FF1 2# 1# 35#.
DBS-2.3/9.2-400
FF1 2# 1# 23# (0-15)#
DBS Manual - Revised April 2000
Chapter 1. System Programming (FF1)
0=No disconnect signal.
1=100 ms signal will be sent.
2=200 ms signal will be sent.
3=300 ms signal will be sent.
4=400 ms signal will be sent.
5=500 ms signal will be sent.
6=600 ms signal will be sent.
7=700 ms signal will be sent.
8=800 ms signal will be sent.
9=900 ms signal will be sent.
10=1-second signal will be sent.
11=1.5-second signal will be sent.
12=2-second signal will be sent.
13=2.5-second signal will be sent.
14=3-second signal will be sent.
15=3.5-second signal will be sent.
Page 1-31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dbs-9.2-400

Table of Contents