Wink Glare Timer

Software Version: CPC-B Version 4.0 or higher
Address: FF1 8# 4# 2# 10# (0-15)#
Description
"Glare" occurs when both ends of the same trunk are seized simultaneously,
resulting in connection between an incoming call and a DBS phone user
attempting to access an outside line.
Use this address to prevent glare from occurring when wink-start signaling is
used. This timer determines how long the DBS will search for an incoming
call on a trunk channel before connecting a DBS extension user to it (60 ms
by default). The timer begins when a wink is received.
Programming
Table 1-46. Wink Glare Timer values
Page 1-156
FF1 8# 4# 2# 10# (0-15)#
Setting
0
The DBS does not check for glare
1
20 ms
2
40 ms
3
60 ms
4
80 ms
5
100 ms
6
120 ms
7
140 ms
8
160 ms
9
180 ms
10
200 ms
11
250 ms
12
300 ms
13
350 ms
14
400 ms
15
450 ms
DBS Manual - Revised April 2000
Section 400-Programming
Wink Glare Timer setting
Default: 3 (60 ms) (see table below)