Setting Modified For Smdr - Panasonic DBS-2.3-400 Programming Manual

Table of Contents

Advertisement

Section 400-Programming

Setting Modified for SMDR

Values have been redefined for the SMDR Start Timer. The following table shows the
enhanced values.
Note: These values apply to CPC-EX only.
Programming
Related Programming
• FF1 (System): SMDR Print
• FF1 (System): Parity Check
• FF1 (System): Odd/Even Parity
• FF1 (System): Baud Rate
• FF1 (System): Stop Bit Length
• FF1 (System): Data Length
• FF1 (System): Serial Port Flow Control (X On/ X Off)
• FF1 (System): SMDR Display Start Timer for CO Calls
• FF1 (System): SMDR Printing Mode 1: Outbound, Inbound, Network
• FF1 (System): SMDR Printing Mode 2: Long Distance and Local Calls
• FF1 (System): SMDR Printing Mode 3: Header Title
• FF3 (Extension) Station Message Detail Recorder (SMDR) Report
DBS-2.3/9.2-400
to specify the SMDR Display Start Timer for CO Calls...
FF1 2# 1# 2# (0-10)#
DBS Manual - Revised April 2000
Appendix C. EX 1.0 Feature Update
0 = 4sec
6 = 16 sec
1 = 6 sec
7 = 18 sec
2 = 8 sec
8 = 20 sec
3 = 10 sec
9 = 25 sec
4 = 12 sec
10 = 30 sec
5 = 14 sec
Page C-43