Red Alarm Relay - Panasonic DBS-2.3-400 Programming Manual

Table of Contents

Advertisement

Chapter 1. System Programming (FF1)

Red Alarm Relay

Software Version: CPC-B Version 4.0 or higher
Address: Master Cabinet: FF1 8# 4# 4# 4# 2# (0 or 1)#
Slave Cabinet:
Description
Determines whether the system closes the alarm relay on the T1 MDF card in
the event of red alarms. A red alarm indicates that a loss of frame (OOF) or
loss of signal has continued for more than 2.5 seconds.
The alarm relay can be connected to an external alarm device such as a
buzzer. (This device must be purchased separately; it is not provided with the
DBS T1.)
The Red Alarm Detection address (FF1 8# 4# 4/5# 2# 1# 0-5#) determines
how many red alarms occur before the relay closes.
Programming
Related Programming
Red Alarm Detection: FF1 8# 4# 4/5# 2# 1# (0-15)#
Red Alarm Counter: FF1 8# 4# 4/5# 3# 3# (0-9000)#
Page 1-184
FF1 8# 4# 5# 4# 2# (0 or 1)#
FF1 8# 4# (4 or 5)# 4# 2# (0 or 1)#
4=Master Cabinet
5=Slave Cabinet
DBS Manual - Revised April 2000
Section 400-Programming
0=Off (Red Alarm relay does not close)
1=On (Red Alarm relay closes)
DBS-2.3/9.2-400