Chapter 1. System Programming (FF1)

AEC Disconnect Signal Duration

Software Version: CPC-AII (all versions) and CPC-B Version 5.0 or higher
Address:
FF1 2# 1# 35# (0-15)#
Description
Use this address to set the duration of a positive disconnect signal sent from
analog extension ports (VB-43621A version of the AEC card). Sending this
signal allows quick disconnect from third-party voice mail systems. By
default, no disconnect signal is sent.
This address applies to CPC-AII and CPC-B. The AEC Disconnect Signal
Duration address for CPC-A (Version 3.3 or higher) is FF1 2# 1# 23# (0-
15)#.
The sending of the AEC disconnect signal can be enabled or disabled on
individual extensions using FF3 (ExtPort)# 46#.
Programming

Table 1-4. AEC Disconnect Signal Duration values

Page 1-44
FF1 2# 1# 35# (0-15)#
Setting
0
No disconnect signal sent
1
100 ms
2
200 ms
3
300 ms
4
400 ms
5
500 ms
6
600 ms
7
700 ms
8
800 ms
9
900 ms
10
1 second
11
1.5 seconds
12
2 seconds
13
2.5 seconds
DBS Manual - Revised April 2000
Section 400-Programming
AEC Disconnect Signal Duration setting
Default: 0 (no signal sent)
(see table below)
Value
DBS-2.3/9.2-400

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dbs-9.2-400

Table of Contents