4.3 Basic Sequence
4.3.1 Basic Sequence of Operations at Power-On
Period
WMUP (warm-up)
WMUPR (warm-up rotation)
PSTBY (printer standby)
T-4-4
Description
While the drive system is at rest and, in addition, until the
surface temperature of the fixing roller reaches 90 deg C.
After the drive system starts up and, in addition, bias
adjustment is under way.
While the machine is ready for a copy/print request signal.
Chapter 4
0000-4450
4-5