YASKAWA SGDH User Manual page 463

Servomotors
Hide thumbs Also See for SGDH:
Table of Contents

Advertisement

Display after
Step
Operation
Alarm generated
1
2
3
4
5
6
7
8
9
Turn OFF the power, and then turn it ON again to make the setting valid.
Digital
Panel
Operator
Operator
DSPL
SET
MODE/SET
(DSPL/SET Key)
(MODE/SET Key)
DATA
ENTER
DATA/
(DATA/SHIFT Key)
(DATA/ENTER K ey)
(Press at least 1 s.)
DSPL
SET
MODE/SET
(DSPL/SET Key)
(MODE/SET Key)
About one second later
DATA
ENTER
DATA/
(DATA/SHIFT Key)
(DATA/ENTER K ey)
(Press at least 1 s.)
Description
Press the DSPL/SET or MODE/SET Key to select the utility func-
tion mode.
Press the UP or DOWN Key to select parameter Fn008.
Note: The digit that can be set will blink.
Press the DATA/ENTER Key once, or DATA/SHIFT Key for
more than one second.
The display will be as shown at the left.
Continue pressing the UP Key until PGCL5 is displayed.
Note: If there is a mistake in the key operation, "nO_OP" will
blink for about one second. The panel operator or digital
operator will return to the utility function mode.
Press the DSPL/SET or MODE/SET Key. This will clear the
multiturn data of the absolute encoder.
When completed, "donE" will blink for about one second.
After "donE" is displayed, "PGCL5" will be displayed again.
Press the DATA/ENTER Key once, or DATA/SHIFT Key for
more than one second to return to the Fn008 display of the utility
function mode.
8-31
8.4 Absolute Encoders
8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents