9 Adjustments

9.5 Analog Monitor

Signals for analog voltage references can be monitored.
To monitor analog signals, connect the analog monitor cable (JZSP-CA01 or DE9404559) to the connector CN5.
The analog monitor signals can be selected by setting parameters Pn003.0 and Pn003.1.
Pin Number
1
2
3, 4
Line Color
Signal Name
Red
Analog monitor 2
White
Analog monitor 1
Black (2 lines)
GND (0 V)
Monitoring Item with Factory Setting
Motor speed: 1 V/1000 min
Torque reference: 1 V/100% rated torque
9-28