5.2.13 SGMUH Servomotors (6000 min
pean Safety Standards
(1) 400 V Servomotors Without Holding Brakes
Select a cable clamp in accordance with the applied cable diameter.
The straight plug type JA06A-22-22S-J1-EB and L-shaped plug type JA08A-22-22S-J1-EB conform to IP67 Protective
INFO
Construction Standard only.
Capacity
Connector on
(kW)
Servomotor
1.0
CE05-2A18-10PD-B
1.5
3.0
JL04HV-2E22-22PE-B
4.0
-1
) Connectors Conforming to IP67 and Euro-
Plug
Straight
CE05-6A18-10SD-
CE05-8A18-10SD-B-
B-BSS
JL04V-6A22-22SE-EB
JL04V-8A22-22SE-EB
or
JA06A-22-22S-J1-EB
JA08A-22-22S-J1-EB
5-35
5.2 Servomotor Main Circuit Wire Size and Connectors
Cable Clamp
L-shaped
CE3057-10A-1
CE3057-10A-2
BAS
CE3057-10A-3
JL04-2022CK(09)
or
JL04-2022CK(12)
JL04-2022CK(14)
Applicable Cable
Range in mm (inch)
(For reference)
φ10.5 (φ0.41) to
φ14.1 (φ0.56)
φ 8.5 (φ0.33) to
φ11.0 (φ0.43)
φ 6.5 (φ0.26) to
φ 8.7 (φ0.34)
φ 6.5 (φ0.26) to
φ 9.5 (φ0.37)
5
φ 9.5 (φ0.37) to
φ13.0 (φ0.51)
φ12.9 (φ0.51) to
φ15.9 (φ0.63)