5 Specifications and Dimensional Drawings of Cables and Peripheral Devices
5.2.12 SGMDH Servomotors (2000 min
5.2.12 SGMDH Servomotors (2000 min
pean Safety Standards
(1) Servomotors With and Without Holding Brakes
Select a cable clamp in accordance with the applied cable diameter.
The straight plug type JA06A-24-10S-J1-EB and L-shaped plug type JA08A-24-10S-J1-EB conform to IP67 Protective
INFO
Construction Standard only.
Capacity
Connector on
Servomotor
(kW)
2.2
JL04V-2E24-10PE-B
3.2
4.0
SGMDH (2000 min
(2)
Servomotor-end
connector
-1
) Connectors Conforming to IP67 and European Safety Standards
Straight
JL04V-6A24-10SE-EB
or
JA06A-24-10S-J1-EB
-1
) Servomotor Main Circuit Connector Pin Arrangement

Without Brakes

Pin No.
Signal
A
Phase U
D
A
B
Phase V
C
B
C
Phase W
D
FG
(Frame Ground)
-1
) Connectors Conforming to IP67 and Euro-
Plug
L-shaped
JL04V-8A24-10SE-EB
or
JA08A-24-10S-J1-EB

With Brakes

Pin No.
A
F
A
G
B
E
B
C
D
C
D
5-34
Applicable Cable
Cable Clamp
Range in mm (in)
(For reference)
φ 9.0 (φ0.35) to
JL04-2428CK(11)
φ12.0 (φ0.47)
φ12.0 (φ0.47) to
JL04-2428CK(14)
φ15.0 (φ0.59)
φ15.0 (φ0.59) to
JL04-2428CK(17)
φ18.0 (φ0.71)
φ18.0 (φ0.71) to
JL04-2428CK(20)
φ20.0 (φ0.79)
Signal
Pin No.
Phase U
E *
Brake terminal
Phase V
F *
Brake terminal
Phase W
G
FG
* No polarity
(Frame Ground)
Signal